From 0–8 MVA AC/DC load banks, transformers and e‑Boilers, including test engineering and reporting.
Load bank rental 0 - 8 MVA (AC & DC)
Engineers, test plans and compliance-ready reports
Fast deployment from Apeldoorn across EU

Discover top-quality, reliable rental solutions for any project. From construction, marine, Health to events, Ukana Rental equips you with the tools needed for success.
Explore a diverse range of top-quality, reliable rental equipment options.

The 100 kW load bank is the ideal solution for testing, commissioning, and maintaining low- to mid-power generation systems. Designed for controlled and accurate load testing, this unit allows you to verify generator and power system performance under real operating conditions — without disrupting live infrastructure.
Our 100 kW load bank is suitable for diesel generators, UPS systems, battery installations, and hybrid energy setups, providing de dependable resistive load testing for planned maintenance, FAT/SAT testing, and compliance checks.
Key Features
Rated power: 100kW
Resistive load configuration for accurate real-world testing
Step-controlled load banks for precise load application
Portable and compact design for easy on-site deployment
Safe and reliable operation, maintained to professional standards
Typical Applications
Generator commissioning and acceptance testing
Periodic generator maintenance and load exerxicing
UPS and battery system testing
Temporary load simulation of power system validation



Our 300–700 kW load banks are engineered for medium to large-scale power testing where higher capacity, stability, and precision are essential. These units are ideal for validating the performance of large diesel and gas generators, UPS installations, battery energy storage systems, and hybrid power setups under real operational conditions.
Designed for demanding environments, this load bank range allows controlled, step-based load testing to simulate real-world demand safely and accurately — without risking live infrastructure or production continuity.
Key Features
Power range: 300kW to 700kW
Resistive or resistive -reactive configurations available
Precise load step control for staged testing and analysis
Industrial-grade construction, suitable for on-site and outdoor use
High airflow, forced-air cooling for coninuous and stable operation
Integrated safety protections inclusing temperature and fan monitoring
Typical Applications
Commisioning and acceptance testing of large generator sets
Load testing during maintenance ane periodic compliaince checks
UPS, inverter, and battery system validation
Temporary load simulation for grid, energy and infrastructure projects

The 1000 kW load bank is designed for high-capacity power testing in critical and mission-essential environments. This unit is ideal for full-scale testing of large generator sets, data centres, grid-connected installations, battery energy storage systems, and industrial power infrastructure where performance, accuracy, and reliability are non-negotiable.
With precise load control and robust industrial construction, the 1000 kW load bank enables safe simulation of real operating conditions during commissioning, load acceptance, maintenance testing, and redundancy validation, without impacting live operations.
Key Features
Rated power: 1000kW
Up to 1000v DC
Resistive or resistive-reactive configurations available
Fine load step control for staged and full-load testing
Forced-air cooling with high airflow for continuous operation
Comprehensive safety protections, includign temperature and fan monitoring
Typical Applications
Full-load and endurance testing of large generator installations
Commissioning and acceptance testing for data centres and utilities
Validation of UPS, battery, and hybrid energy systems
Grid support and temporary load simulation during infrastrucure projects

Ukana Rentals specialises in the rental of professional load banks for testing power generation and energy systems. We support organisations that require reliable, controlled load testing for generators, UPS systems, batteries, and critical power installations — whether for commissioning, maintenance, acceptance testing, or periodic compliance.
Our focus is simple: ensure power systems perform exactly as intended when it matters most. We provide high-quality resistive and reactive load banks, maintained to strict technical standards and supported by knowledgeable specialists who understand the realities of on-site testing.
We work with energy companies, data centres, industrial facilities, contractors, and utilities that cannot afford uncertainty. That is why we combine dependable equipment with clear advice, flexible rental periods, and fast deployment across Europe.
At Ukana Rentals, we go beyond supplying equipment. We think along with our clients, help define the right testing setup, and ensure each load test is executed safely, efficiently, and in line with project requirements.
Proven testing. Reliable power. No compromises.
FAQs
Quick Answers to Your Rental Questions at Ukana!
A resistive load bank applies a purely resistive electrical load to a power source, meaning the voltage and current are in phase. This simulates straight real power usage (kW) and is ideal for testing generator output and heating/cooling systems under full load.
A reactive load bank introduces inductive or capacitive elements that cause current and voltage to shift in phase (non-unity power factor). This is important when you need to replicate real-world electrical systems with motors, transformers or other inductive loads.
A resistive/reactive (or RLC) load bank combines both resistive and reactive loads. It can simulate actual load conditions more accurately by adjusting both real power (kW) and reactive power (kVAr), allowing comprehensive testing across a range of power factor scenarios.
Yes. Load banks can definitely be rented for emergency testing, for example to verify a generator or UPS system is capable of carrying critical systems during unexpected outages. Rental units are particularly valuable when you need immediate load testing support without long-term equipment ownership.
At Ukana, temporary load bank rental is available and tailored to your schedule and urgency, so you can perform emergency tests with the correct load configuration and size.
Yes. Most professional load bank rental providers — including Ukana — offer both short-term and long-term rental contracts.
Short-term rentals are ideal for one-off tests, commissioning, emergency testing or periodic maintenance.
Long-term rentals suit extended projects, multiple test events, or when you want to free up capital by renting instead of buying.
Flexible rental terms help you match the equipment to your project timeline and budget.
A load bank is a device used to apply a controlled, artificial electrical load to a power source such as a generator, UPS system, transformer or power supply. By simulating real operating conditions, a load bank allows you to test whether your power system can safely and reliably deliver its rated capacity.
You need a load bank to verify performance, reliability and compliance without risking live equipment. Load bank testing is commonly used during commissioning, maintenance, acceptance testing and emergency preparedness. It helps identify problems such as insufficient capacity, voltage instability, cooling issues or control failures before they cause unplanned downtime.
Load banks are especially important in critical power applications—including data centers, hospitals, industrial facilities and energy projects—where failure is not an option. By using a load bank, you gain confidence that your power system will perform exactly as required when it matters most.
Load bank rental is often the best choice when:
You only need temporary load testing, such as one-off commissioning, maintenance or certification.
You want to avoid the upfront cost of purchasing equipment you use infrequently.
Your project timeline doesn’t align with owning full-time equipment.
You need rapid deployment for emergency testing or troubleshooting.
You are testing multiple power sources or need different configurations over time.
Rental allows flexibility in capacity, configuration (resistive/reactive), and duration without ownership commitment.
Selecting the right size depends on the power (kW or kVA) of the system you want to test:
Calculate the maximum output of your generator, UPS or electrical source.
Choose a load bank with equal or greater capacity (Ukana provides from ~100 kW up to several MW and units can be linked for higher capacity).
Consider your testing goals — full-load testing requires capacity close to nameplate values, whereas partial-load testing can use smaller units.
If you’re unsure, rental providers generally offer sizing advice during the inquiry or quotation process to ensure proper match.